unknown4597704.310144,6648562.7133984NOBaerum1075060Cultural-E - Norwegian Demo (Baerum)<p><b>PEB Demo Conext</b></p><p>Assisted living and welfare technology.</p>
<p>Located in Rural/ suburb area.</p>
<p>Handover from general contractor to demo owner, Bærum municipality, in Q2 2021. </p>
<p>Additional information available in Atlas-energy culture layer and in D2.1 (please visit Cultural-E website).</p><p><b>Building Owner</b></p>BAERUM MUNICIPALITYFIGURE_17.jpg<p><b>PEB Key Features</b></p><p>12 apartments + common areas, total 1300 m2, three story building. Average floor area for one apartment: 60 m2.</p>
<p>Part of Bærum muncipalities Climate-strategy 2030; BREEAM Excellent, FutureBuilt project, passive house standard (NS 3701).</p>
<p>PV (23 kWp).</p>
<p>Geothermal heat-pump (30 kW).</p>
<p>Balanced mechanical ventilation with heat recovery (84-86%). Decentralized for apartments and central for common areas.</p>
<p>Central control and management system w. energy monitoring.</p>FIGURE_18.JPG<p><b>PEB Technologies Integration</b></p><p>1. PV (23 kWp).</p>
<p>2. Energy management (House management system).</p>
<p>3. Optimization strategies and building flexibility.</p>
<p>Further uppdates will be available soon.</p>FIGURE_20.JPGFIGURE_19.JPG<p><b>PEB Demo community and partnership </b></p><p>Baerum Municipality, Building Owner</p>
<p>SINTEF, Technical Adviser</p>FIGURE_17.JPGFIGURE_22.jpg<p><b>References</b></p><p>Norwegian building code (TEK17)</p>
<p>Passive house standard (NS3701)</p>
<p>BREEAM-NOR Excellent</p>
<p>FutureBuilt</p>https://www.cultural-e.eu/norwegian-demo/379627.816441,5625955.5090783FRLeers305451Cultural-E - French Demo (Leers)<p><b>PEB Demo Conext</b></p><p>The French Demo is a residential building composed by 19 rented social housing dwellings. It is located in the north regions of the country at the Lille metropolis.</p>
<p> Low altitude, important rainfalls (763mm annual mean) and an average temperature of 11°C. Additional information available in Atlas-energy culture layer for France and in D2.1 (please visit Cultural-E website).</p>
<p>Expected delivery by end of 2022.</p><p><b>Building Owner</b></p>VILOGIAFIGURE_01.jpg<p><b>PEB Key Features</b></p><p>Ground floor + 4 floors</p>
<p>19 units</p>
<p>1345 m²</p>
<p>Performance targets : </p>
<p>1. Cpe ? Cpe,max – 20% = 56 kWh EP /m² </p>
<p>2. Balance the consumption of the 5 regulatory uses by a photovoltaic production, i.e. (Cep including PV) ? 0</p>
<p>Energy systems: PHP with dual flow ventilation and heat recovery, 1 unit per dwelling for heating and DHW</p>FIGURE_02.JPG<p><b>PEB Technologies Integration</b></p><p>1. PHP with dual flow ventilation and heat recovery, 1 per dwelling for heating and DHW</p>
<p>2. Triple glazing windows</p>
<p>3. HMS</p>FIGURE_03.JPG<p><b>PEB Demo community and partnership </b></p><p>Architect: Blaq</p>
<p>Engineering consultant: Energélio</p>
<p>Cultural-E project advisor: Nobatek</p>
<p>Contractors: to be procured</p>FIGURE_04.jpgFIGURE_05.jpgFIGURE_06.jpg<p><b>References</b></p><p>RT 2012: French Thermal Regulation for new buildings.</p>
<p>The aim of Cultural-E is to achieve 80% of the maximum consumption authorized by this norm or even less if possible (see "performance targets" above)</p>
<p>PEB Definition established by the Cultural-E project.</p>https://www.cultural-e.eu/french-demo/2654249.235876,4946390.8507212ITCastenaso1094545Cultural-E - italian Demo (Castenaso)<p><b>PEB Demo Conext</b></p><p>The municipality of Castenaso is located near Bologna and has a history dating back to Roman times. The town is located in a rural setting, crossed by the river Idice, and is rich in parks and countryside. The population is 15,000. Not far away, there is a waste-to-energy plant.</p>
<p>The location has a humid temperate climate with very hot and humid summers and rather cold and wet winters. </p>
<p>In recent years, summers that were longer and hotter than normal occurred, in which there were also long periods of drought. Average rainfall in the town ranges from 600 to 900 mm/y and is usually concentrated in spring and autumn.</p>
<p>In winter, snowfalls can occur and sometimes very abundant. Frequent night frosts.</p>
<p>The modest windiness contributes to the formation of fogs and mists and to the permanence of a high air pollution. Occasionally strong winds.</p>
<p>Tenants are expected to move into their dwellings in 2023.</p>
<p>The apartments are made in different sizes for the middle class, dedicated to singles, families, and the elderly.</p>
<p>Additional information available in Atlas-energy culture layer and in D2.1 (please visit Cultural-E website).</p><p><b>Building Owner</b></p>ABITCOOPFIGURE_14.JPG<p><b>PEB Key Features</b></p><p>The pilot buildings are two similar buildings (A,B).</p>
<p>Each building consists of three floors. Pilot A includes 7 apartments, pilot B includes 6 apartments.</p>
<p>Garage with dedicated e-vehicle charging station at ground level. Garden.</p>FIGURE_15.JPG<p><b>PEB Technologies Integration</b></p><p>1. Photovoltaic system on the roof combined with electrical storage battery in the stairwell dedicated to each dwelling. Wall thermal insulation.</p>
<p>2. Active window system, with controlled shading.</p>
<p>3. Underfloor heating, DHW, air cooling and ventilation provided by PHP system.</p>
<p>4. Air movement by Vortice fans in most rooms.</p>
<p>5. Cloud-backed HMS system monitors environmental conditions and energy consumption by sensors and energy metering, and controls integrated systems.</p>FIGURE_16.JPG<p><b>PEB Demo community and partnership</b></p><p>Abitcoop, Building Owner and Building Designers</p>
<p>Endorsement by Castenaso municipality</p>FIGURE_14.JPG<p><b>Operational strategy and expected results</b></p><p>User comfort and preferences are prioritized. Therefore, based on room/dwelling occupancy and deviation from comfort conditions, heating/cooling systems are operated together with window shading and air movement in order to reduce energy consumption and to exploit PV energy production and the stored electrical energy.</p><p><b>References</b></p><p>Technical guidelines: ISO/UNI.</p>
<p>Building certification process: CasaClima A.</p>
<p>Relevant policies and regulations: national and regional laws.</p>
<p>PEB Definition established by the Cultural-E project.</p>https://www.cultural-e.eu/italian-demo/1519328.951562,5397504.7708261DEOstfildern930749Cultural-E - German Demo (Ostfildern)<p><b>PEB Demo Conext</b></p><p>The project is located in Ostfildern near Stuttgart. At an altitude of approx. 410 m above sea level the climate is classified as warm and temperate. Ostfildern is a city with a lot of precipitation. The annual average temperature in Osfildern is around 10 °C. The annual rainfall is around 877 mm, and the climate is classified as continental.</p>
<p>The demo consists of a single building owned by Wohnbau Studio GmbH (private real estate). With a mix of different floor plans and sizes, an attempt is made to appeal to a wide range of prospective tenants. The residential units will be realized as rental apartments. A large part of the lighting design will be pre-installed on-site in order to ensure energy-efficient lighting. The kitchens are also made available to future tenants, including energy-saving appliances.</p>
<p>A “power-saving switch” in the entrance area enables the tenant to switch off all secret stand-by electricity consumers centrally when leaving the apartment.</p><p><b>Building Owner</b></p>Wohnbau StudioFIGURE_07.jpg<p><b>PEB Key Features</b></p><p><b>N of dwellings: </b>21 + 1 commercial unit</p>
<p><b>N of floors: </b>4 (ground floor + two upper floors + attic)</p>
<p><b>Average surface area per apartment: </b>
Commercial unit, approx. 750 m2 – Residential units, average approx. 75 m2</p>
FIGURE_23.JPG<p><b>PEB Technologies Integration</b></p><p>1. Air-to-water heat pump.</p>
<p>2. Photovoltaic system on the roof combined with electrical storage battery.</p>
<p>3. House Management System (HMS).</p>
<p>4. Freshwater station.</p>
<p>5. Commercial area on the ground floor ceiling fan.</p>
<p>6. Decentralized Heat Pump (PHP) 5 apartments in the attic.</p>
<p>7. Underfloor heating.</p>
<p>8. Exhaust ventilation system.</p>
<p>9. Execution of the windows not yet finally clarified – possibility for approx. 10 active window system.</p>
<p><b>PEB Demo community and partnership </b></p><p>General contractor: to be procured</p><p>Energy consultant: SIZ energieplus and EGS-plan</p>FIGURE_12.jpgFIGURE_13.jpg<p><b>References</b></p><p>EH40 (efficiency house 40) Standard.</p>